Error 108 or 1P4: low heating pressure
The boiler has detected low pressure in the heating circuit and has shut down to protect itself. Depending on the model, the warning shows as 108, sometimes together with the word FILL, or as 1P4.
What it means
The heating circuit is a closed loop: the water goes to the radiators or underfloor heating and back to the boiler. It needs a minimum pressure to work. With the heating cold, the pressure gauge usually reads between 1 and 1.5 bar.
When the pressure falls below the minimum, the boiler stops so that the pump and the heat exchanger don't run without enough water.
Most likely causes
- Bleeding the radiators. Letting the air out lowers the pressure. That's to be expected: it just needs topping up.
- A leak in the system: a radiator, a valve, a fitting or the underfloor heating. If you have to top up more than once or twice a year, there's most likely a leak.
- The expansion vessel has lost its charge. Water expands as it heats up and the vessel absorbs that increase. Without its charge, the pressure rises sharply when the system is hot, the pressure relief valve discharges water and, once it cools, the pressure drops.
- The pressure relief valve is dripping because of wear or limescale.
What you can check yourself
Without tools and without opening the unit.
- Check the pressure gauge with the heating cold and note down the pressure. On many models it's also shown on the display.
- Look for traces of water under the boiler, on the radiators and around the valves.
- Watch the pressure with the heating running. If it rises to nearly 3 bar and then drops, tell us: it points to the expansion vessel.
- Topping up is easy, but the filling valve must be closed properly afterwards. If it's left open, the circuit keeps filling and ends up discharging through the pressure relief valve: water on the floor.
Call us before you touch anything. If you want to top up yourself, we'll take a minute on the phone to explain where your model's filling valve is and how to close it properly. A water damage claim costs far more than a visit. And if you have to top up often, book an engineer: there's most likely a leak or the vessel has lost its charge.
If the water heater, boiler or heat pump is leaking a lot of water: turn off the main water stopcock in your home and call us on 871 559 176. That stops the leak and saves you from water damage.
If you smell gas: turn off the gas at the shut-off valve and open the windows. Don't touch any switches or plugs, and call us from outside the property.
If the unit is smoking or getting hotter than it should: switch it off, disconnect it from the mains and call us.
If we come out
What we check and how to stop it happening again
What the engineer usually checks
- Finding the leak, in the boiler and in the system
- Expansion vessel pre-charge pressure
- Pressure relief valve and filling valve
- Bleeding the circuit and working pressure
How to catch it early
An expansion vessel with no pressure or a small leak can't be seen from the outside, but a service picks them up in a few minutes. Spotting it in October saves you from being left without heating in the middle of winter.
See the maintenance plansStill not sorted?
Book an engineer and give us the code and the model of your unit. That way we know what to bring.